Part Number Hot Search : 
ST19NR66 BDX33C T2N5551 ISL59119 MKP1846 SR2050 NDB5060 OM4215SW
Product Description
Full Text Search
 

To Download UV28-15 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 (R)
MICROVERTER
RO
MICROVERTER
(R)
DC-DC Converters, 200-250 Watt Family
World's Most Advanced Ultra High Density Single and Triple Output DC-DC Converters Up to 252 Watts 28, 48, and 300 VDC Input
Evaluation Boards and Triple Output Modules Available
DESCRIPTION
MicroVerter modules are high density DCDC converters designed for use in telecom and other centralized modular and distributed power applications. Three input voltage ranges are available and all use metal PC boards, planar transformers, and surface mount construction to produce up to 252 watts in a tiny package.
MODEL SELECTION Model Number Input 28 VDC 48 VDC 300 VDC (36-72V) (220-400V) (20-32V) Single Output V28-2 V48-2 V300-2 V28-3 V48-3 V300-3 V28-5 V48-5 V300-5 V28-8 V48-8 V300-8 V28-12 V48-12 V300-12 V28-15 V48-15 V300-15 V28-24 V48-24 V300-24 V28-28 V48-28 V300-28 Triple Output V28-T512 V48-T512 V300-T512 Output Voltage Current 2.1V 3.3V 5V 8V 12V 15V 24V 28V 5V 12V -12V 5V 15V -15V 60A 50A 40A 30A 20A 16A 10A 9A 35A* 3A* 3A* 35A* 3A* 3A*
F E AT U R E S
Miniature Size High Density - Up to 58 W/in.3 Constant Frequency - 370KHz Parallelable with Current Sharing Fault Tolerant - n+m Redundancy Extremely Low Thermal Resistance Output Good Signal Synchronization Option UL, CSA, & TUV Approvals Non-Shutdown Over Voltage Protection Logic On-Off Thermal Protection Current Limit/Short Circuit Protection Isolated Auxiliary Outputs
V28-T515
V48-T515 V300-T515
*Maximum Total Output Power 185 W. (See p. 19 for min. load requirements.)
Option: --S Synchronization Feature
12
RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com
M I C R O V E R T E R (R) V 2 8 S E R I E S S P E C I F I C AT I O N S
INPUT Input voltage Brownout In rush charge Input reflected ripple No load power dissipation Logic disabled power in Input ripple rejection Input overvoltage OUTPUT (Singles and Main Output of Triple) Set point accuracy Load regulation Line regulation Ripple Trim range Remote sense compensation OVP (non shutdown auto. recovery) Current Limit (auto.recovery) Current sharing (automatic) Transient response singles Transient response main output triples Transient response (see page 19) Temp drift Efficiency (see curves page 17) OUTPUT (Auxiliary Outputs of Triples) Set point accuracy Load regulation Line regulation Ripple Current Limit (auto. recovery) Transient response Transient response Transient response Temp drift CONTROL Turn on time Logic turn on time Logic disabled current ISOLATION Input to output Input to case Output to case Input to output capacity THERMAL Operating temperature Automatic shut down temperature Thermal resistance case to ambient WEIGHT singles triples SIZE singles triples (outline drawings see page 16) 1000 1000 200 2200 -40 +100 +100 +110 VDC VDC VDC pF C case C case C/w C/w oz. oz. inches inches consult factory for procedure MIN 20 18 TYPICAL 24-28 2.6x10-4 20 1.5 7.5 0.35 60 32 60 1 .2 .2 3 0.5 120* 110-120 5 50 200 .02 MAX 32 UNITS VDC VDC Coulombs % watts watts watts dB VDC % % % %p-p % V total % % % s s %/C CONDITIONS 75% full output power full load, nominal line singles triples @ 120 Hz no damage to units no load 0 to full load over range 0 to 20 MHz consult factory for extended range * or Vout +.5V whichever is greater full load full load 20-80% load,.5A/s, Vout 1% 10-20A, aux. loads 2.5A, .25A/s, Vout 1%
.02 .02 1 10
0.5 .2 .01 .25 110-120 200 200 200 .06 2.5 1 1
1 .5 .1 .5
% % % %p-p % s s s %/C ms ms mA
10A on main, no load auxiliaries 0 to full load over range 0 to 20 MHz full load 20-80% load, Vout within 1% low line to high line, Vout 1% 50-100% load, Vout 1%
input power applied, Vout 1% Vout within 1% sink
+105 4.2 3.3 7 9 0.5x2.4x3.6 0.5x2.4x4.6
single @ Tc=100C triple @ Tc=100C
RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com
13
V28
SERIES
SERIES
M I C R O V E R T E R (R) V 4 8 S E R I E S S P E C I F I C AT I O N S
INPUT Input voltage Brownout In rush charge Input reflected ripple No load power dissipation Logic disabled power in Input ripple rejection Input overvoltage OUTPUT (Singles and Main Output of Triple) Set point accuracy Load regulation Line regulation Ripple Trim range Remote sense compensation OVP (non shutdown auto. recovery) Current Limit (auto.recovery) Current sharing (automatic) Transient response singles Transient response main output triples Transient response (see page 19) Temp drift Efficiency (see curves page 17) OUTPUT (Auxiliary Outputs of Triples) Set point accuracy Load regulation Line regulation Ripple Current Limit (auto.recovery) Transient response Transient response Transient response Temp drift CONTROL Turn on time Logic turn on time Logic disabled current ISOLATION Input to output Input to case Output to case Input to output capacity THERMAL Operating temperature Automatic shut down temperature Thermal resistance case to ambient singles triples SIZE singles triples (outline drawings see page 16) WEIGHT 3000 1500 500 2200 -40 +100 +100 +110 MIN 36 32 TYPICAL 48 2.6x10-4 20 2.5 7.5 1 60 72 100 1 .2 .2 3 0.5 120* 110-120 5 50 200 .02 MAX 72 UNITS VDC VDC Coulombs % watts watts watts dB VDC % % % %p-p % V total % % % s s %/C CONDITIONS 75% full output power full load, nominal line singles triples @ 120 Hz no damage to unit no load 0 to full load over range 0 to 20MHz consult factory for extended range * or Vout +.5V whichever is greater full load full load 20-80% load,.5A/s, Vout 1% 10-20A, aux. loads 2.5A, .25A/s, Vout 1%
V48
.02 .02 1 10
0.5 .2 .01 .25 200 200 200 .06 2.5 1 1
1 .5 .1 .5 110-120
% % % %p-p s s s %/C ms ms mA VDC VDC VDC pF C case C case C/w C/w oz. oz. inches inches
10A on main, no load auxiliaries 0 to full load over range 0 to 20 mHz % full load 20-80% load, Vout within 1% low line to high line, Vout 1% 50-100% load, Vout 1%
input power applied, Vout 1% Vout within 1% sink consult factory for procedure
+105 4.2 3.3 7 9 0.5x2.4x3.6 0.5x2.4x4.6
single @ Tc=100C triple @ Tc=100C
14
RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com
M I C R O V E R T E R (R) V 3 0 0 S E R I E S S P E C I F I C AT I O N S
INPUT Input voltage Brownout In rush charge Input reflected ripple No load power dissipation Logic disabled power in Input ripple rejection (120Hz) OUTPUT (Singles and Main Output of Triple) Set point accuracy Load regulation Line regulation Ripple Trim range Remote sense compensation OVP (non shutdown auto. recovery) Current Limit (auto.recovery) Current sharing (automatic) Transient response singles Transient response main output triple Transient response (See page 19) Temp drift Efficiency (See curves page 17) OUTPUT (Auxiliary Outputs of Triples) Set point accuracy Load regulation Line regulation Ripple Current Limit (auto.recovery) Transient response Transient response Transient response Temp drift CONTROL Turn on time Logic turn on time Logic disabled current ISOLATION Input to output Input to case Output to case Input to output capacity THERMAL Operating temperature Automatic shut down temperature Thermal resistance case to ambient WEIGHT SIZE singles triples singles triples 4500 2500 500 5700 -40 +100 +100 +110 MIN 220 180 TYPICAL 300 4.5x10-5 20 2.5 7.5 1 60 1 .2 .2 3 0.5 120* 110-120 5 50 200 .02 MAX 400 UNITS VDC VDC Coulombs % watts watts watts dB % % % %p-p % V total % % % s s %/C CONDITIONS 75% full output power full load, nominal line singles triples @ 120 Hz no load 0 to full load over range 0 to 20 MHz consult factory for extended range * or Vout +.5V whichever is greater full load full load 20-80% load,.5A/s, Vout 1% 10-20A, aux. loads 2.5A, .25A/s, Vout 1%
10
.02 .02 1 +10, -30
0.5 .2 .01 .25 110-120 200 200 200 .06 250 2 1
1 .5 .1 .5
% % % %p-p % s s s %/C ms ms mA VDC VDC VDC pF C case C case C/w C/w oz. oz. inches inches
10A on main, no load auxiliaries 0 to full load over range 0 to 20 mHz full load 20-80% load, Vout within 1% low line to high line, Vout 1% 50-100% load, Vout 1%
input power applied, Vout 1% Vout within 1% sink consult factory for procedure
+105 4.2 3.3 7 9 0.5x2.4x3.6 0.5x2.4x4.6
single @ Tc=100C triple @ Tc=100C
(outline drawings see page 16)
RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com
15
V300
SERIES
OUTLINE
RO
MICROVERTER
SINGLE OUTPUT
(R)
Outline Drawings
MICROVERTER
(R)
Note: Filled pins (marked *) are not provided in V300 series models
TRIPLE OUTPUT
Note: Filled pins (marked *) are not provided in V300 series models
16
RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com
Performance Data
EFFICIENCY CURVES 2, 3, & 5V Output Models
85 EFFICIENCY, PERCENT
5V
12 & 24V Output Models
90 EFFICIENCY, PERCENT
80
3.3V
85
12V
24V
75
2V
80
70
OUTPUT POWER, WATTS
OUTPUT POWER, WATTS
Triple Output Models
85 EFFICIENCY, PERCENT EFFICIENCY, PERCENT 85
Triple Output Models
80
5V@ 22A
80
75
5V@ 13A
75
5V@5A
70
50
100
150
200
70
50
100
150
200
OUTPUT POWER, WATTS
5V Load Fixed, Aux. Output Loads Varied From 0 to 3A Each
OUTPUT POWER, WATTS
Aux. Loads Fixed at 2A, 5V Load Varied All Loads Varied
Note: Typical Efficiency for Tc = 25C and Nominal Input. Input and Output Measured at the Pins.
RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com
17
MICROVERTER
50
100
150
200
75
50
100
150
200
250
(R)
PERFORMANCE
PERFORMANCE
RO
MICROVERTER
(R)
Performance Data (continued)
THERMAL PERFORMANCE
Thermal Performance-Single Output
5
100 OUTPUT POWER, % OF FULL LOAD
4
75
3 2
50
1
25
(R)
0
MICROVERTER
0
25 50 75 AMBIENT TEMPERATURE, C
100
1 - With No Heatsink and No Airflow 2 - With 2005 Heatsink and No Airflow or, with a 2.2C/W Heatsink 3 - With 2005 Heatsink and 200 LFM Airflow or, with a 1.8C/W Heatsink 4 - With 2005 Heatsink and 400 LFM Airflow or with a 1.2C/W Heatsink 5 - Output Power vs. Case Temperature. No Derating Required for Tc<100C
Thermal Performance-Triple Output Models
5
100 OUTPUT POWER, % OF FULL LOAD
4
75
3 2
50
1
25
0
0
25 50 75 AMBIENT TEMPERATURE, C
100
1 - With No Heatsink and No Airflow 2 - With 2006 Heatsink and No Airflow or, with a 2.0C/W Heatsink 3 - With 2006 Heatsink and 200 LFM Airflow or, with a 1.5C/W Heatsink 4 - With 2006 Heatsink and 400 LFM Airflow or with a 1.0C/W Heatsink 5 - Output Power vs. Case Temperature. No Derating Required for Tc<100C
18
RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com
OUTPUT RIPPLE & TRANSIENT RESPONSE
Output Ripple Output Ripple
1 1 s 50 mV 1 Vout 50 s 100mV 2 Iout 50 s 10A 1 5V
Transient Response Transient
2 100 MS/s MODEL V48-5. 48V INPUT, 40A LOAD, DSO, 400MHZ ANALOG BW, 100 MS/s SAMPLING. 100 MS/s MODEL V48-5 LOAD STEP 8A-32A-8A. CURRENT SLEW RATE 0.5A/s.
0A
MINIMUM LOAD - TRIPLES
Minimum 5V Load vs. Auxiliary Output Power
V28 & V48-Triple Output Models 2.0 2.0
Minimum 5V Load vs. Auxiliary Output Power y
V300 Triple Output Models
1.5 5V LOAD A 5V LOAD A
1.5
1.0 Tc=100C 0.5 Tc=70C 0.0 30 36 42 48 54 60 66 72 78 84 90 AUXILIARY OUTPUT POWER, WATTS
1.0
Tc=100C
0.5
Tc=25C
0.0 30 36 42 48 54 60 66 72 78 84 90 AUXILIARY OUTPUT POWER, WATTS
RO Associates, Inc. * Sunnyvale, CA * 408 744-1450 * Fax: 408 744-1521 * email: sales@roassoc.com
19
MICROVERTER
(R)
PERFORMANCE


▲Up To Search▲   

 
Price & Availability of UV28-15

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X